Fluke Ti9

  • Fluke Ti9
  • Mới

0VNĐ

Model NumberFluke Ti9
Other Features
Detector size160 x 120
Detector typeUncooled microbolometer, focal plane array
Field of view (FOV)23º horizontal x 17º vertical
Spatial resolution (IFOV)2.5 mrad
Minimum focus distance15 cm (approx. 6 in)
Thermal sensitivity (NETD)≤0.20 °C at 30 °C (200 mK)
Detector data acquisition/
###Image frequency
9 Hz
FocusManual, 1-hand focus
IR digital zoomNo
Spectral band7.5 µm to 14 µm
Transmission correction (On Imager)No
Reflected background temperature correction (On Imager)In software only
Measurement modes
CenterpointYes
Center box (area, min/max, average)In software only
User defined spots/boxesIn software only
Advanced on-board analysis functionsNo
User defined field/text annotationsNo
Voice annotationNo
Automatic hot and cold spotsIn software
Image presentation
Digital display3.6" High Resolution LCD
Video outputNo
Palettes4
Optional lenses
Image and data storage
Storage mediumSD memory card (2 GB), stores at least 1200 fully radiometric (.is2) IR-Fusion images or 3000 basic IR images (.bmp or .jpg)
On imager file formatsBMP, IS2
File formats supported in softwareBMP, JPG, GIF, PNG, TIF, WMF, EXIF and EMF
Imager features
Fully radiometricYes
Flash and torch lightNo
Laser pointerNo
Windows based navigation menuYes
AutoCapture (Programable Image Capture)No
Software includedYes (SmartView)
Environmental and mechanical design
Operating temperature-10 to +50°C (14 °F to 122 °F)
Storage temperature-20 to +50°C (-4 °F to 122 °F) without batteries
Relative humidity10% to 90% non-condensing
Water and dust resistantIP54
Weight (including batteries)1.2 kg (2.65 lb)
Camera size (HxWxD)0.27 x 0.13 x 0.15 m
(10.5 in x 5 in x 5 in)
Warranty2 years
Power
Battery typeNiMH Rechargeable batter pack
Battery operating time3-4 hours continuous
Battery re-charge time2 hours for full charge
AC operation (110/220 VAC, 50/60 Hz)Yes
Automatic shut downYes
Sleep modeYes
Applications
Electrical distribution/power generationYes
In plant electricalYes
ElectromechanicalYes
Mechanical systemsYes
Process monitoring and installationsYes
Building diagnosticsNo
IR-Fusion Technology
IR-Fusion technologyNo
Full thermalYes
Full visual lightNo
AutoBlend™No
Picture in pictureNo
Color alarmIn software only
Temperature measurement
Temperature range-20 ˚C to 250 ˚C in 2 ranges
(-4 ˚F to 482 ˚F in 2 ranges)
High temperature optionNo
Accuracy±2 °C or 2% whichever is greater
Emissivity correctionIn software only

No customer comments for the moment.

Write a review

Fluke Ti9

Fluke Ti9

Write a review

Related Products